- Output: 1350W / 1500 VA
- Input: 82-144 @ 50/60 Hz ±3 Hz
- 8 x NEMA 5-15R Battery Backup Outlets
- 1 x NEMA 5-15P Input Connection (8.01')
- 645 Joule Surge Energy Rating
- Recharge Time: up to 3 Hours
- Line Interactive Topology
- Sine Waveform
- SmartConnect Port for External Battery
Designed for servers, point-of-sale, routers, switches, hubs, and other network devices, the Smart-UPS X Battery Backup & Surge Protector with SmartConnect from APC has a 2 RU form factor and delivers intelligent and efficient network power protection from entry level to scalable runtime. It can provide up to 5.2 minutes of use when running a full load of 1350W and up to 14.5 minutes of use when running a half load of 675W
This Smart-UPS X features an output of 1350W / 1500 VA, a nominal input of 120V @ 50/60 Hz ±3 Hz, and an input voltage range of 82-143V that may be adjusted to 75-154V, eight NEMA 5-15R battery backup outlets, an 8.01' NEMA 5-15P input connection, a surge energy rating of 645 joules, line interactive topology, and a sine waveform output. Included PowerChute Network Shutdown management software helps to provide unattended, yet proper shutdowns of network operating systems, and also included is an Ethernet cable, rack-mounting hardware, rack-mounting support rails, removable support feet, an RS-232 cable, and a USB cable.
The APC SmartConnect ports allow the run time of this unit to be extended. When using five SMX48RMBP2U external battery packs, this UPS can last for over 2 hours at 1200W. You'll also be able to view the status of your UPS through a secure web portal. Through this remote management interface, you'll receive automatic notifications, firmware updates, and advanced support.
Intelligent Battery Management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Power Conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery.
Disconnected Battery Notification
Warns when a battery is not available to provide backup power.
Automatic Restart of Loads After UPS Shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic Self-Test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Temperature-Compensated Battery Charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Adjustable Voltage-Transfer Points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable Voltage Sensitivity
Provides the ability to adapt the UPS for improved performance in specific power environments or generator applications.
User-Replaceable Batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries, thus reducing the Mean Time to Repair (MTTR).
Battery Failure Notification
Provides early-warning fault analysis on batteries, thus enabling timely preventive maintenance.
Protective Failure Notification
Provides early-warning fault analysis ensuring proactive component replacement.
Hot-Swappable Batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Resettable Circuit Breakers
Enables a quick recovery from overload events.
Safety-Agency Approved
Helps ensure the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Serial Connectivity
Provides management of the UPS via a serial port.
USB Connectivity
Provides management of the UPS via a USB port.
LED Status Indicators
Quickly understand unit and power status with visual indicators.
Network Manageable
Provides remote power management of the UPS over the network.
Audible Alarms
Actively lets you know if the unit is on battery, if the battery is low, or if there is an overload condition.
Secured and trusted checkout with

- Omschrijving
-
Details
GeneralTotal Outlets 8 x NEMA 5-15R (4 Transformer-Sized) Protected Outlets 8 x NEMA 5-15R (Battery and Surge) Plug Type NEMA 5-15P Data Line Protection RJ45 Communications USB via Type-B
Serial via RJ45Emergency Power Off (EPO) Support Yes Noise Filtering 5% Topology Line Interactive PowerSurge Energy Rating 645 Joules Maximum Current 12 A Maximum Wattage 1350 W Nominal Input Voltage 120 VAC Input Voltage Range 82 to 144 VAC Input Voltage Adjustable Range 75 to 154 VAC Input Frequency 50/60 Hz ± 3 Hz (Auto Sensing) Nominal Output Voltage 120 VAC Output Frequency 50/60 Hz ± 3 Hz Voltage Distortion <5% Load Capacity 1500 VA Circuit Breaker Rating 1000000 A Thermal Dissipation 133 BTU/Hour Maximum Efficiency 98.85% Power Factor Correction 0.9 Waveform Sine Wave BatteryChemistry Lead-Acid Full-Load Runtime 5.2 Minutes Half-Load Runtime 14.5 Minutes Charging Time 3 Hours User Replaceable Yes Replacement Battery APCRBC115 Hot-Swap Support Yes External Battery Connection 2 x IEC Jumper EnvironmentalOperating Temperature 32 to 104°F / 0 to 40°C Operating Humidity 0 to 95% Storage Temperature 5 to 113°F / -15 to 45°C Operating Altitude 0 to 10,000' / 0.0 to 3048 m Storage Altitude 0 to 50,000' / 0.0 to 15,240 m Noise Level 40 dBA PhysicalCable Length 8.01' / 2.44 m Rackmount Size 2 RU Dimensions (W x H x D) 17.01 x 3.5 x 19.29" / 43.21 x 8.9 x 49 cm Weight 54.72 lb / 24.82 kg Packaging InfoPackage Weight 65.7 lb Box Dimensions (LxWxH) 24.5 x 23.5 x 9.75" - Reviews
-
Schrijf je eigen recensie
- Labels
-