Back UPS PRO BR 1350VA,10 Outlets, 2 USB Charging Ports, AVR, LCD interface, LAM
High Performance Computer and Electronics UPS for Premium Power Protection
Includes: coaxial cable, USB cable, User Manual
- Audible alarms
Provides notification of changing utility power and UPS power conditions
- Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Battery backup and surge protection
Outlets provide abundant runtime for network gateway equipment and other critical low-power devices, allowing for hours of internet access during a power outage.
- Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
- Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
- Building Wiring Fault Indicator
This LED informs users of potentially dangerous wiring problems in the wall circuit.
- Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
- EMI and RFI noise filtering
Reduces line noise that can cause data loss and keyboard errors.
- ENERGY STAR for UPS
Establishes that the efficiency of the UPS is in the top 25% of the market as verified by third party testing
- Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
- PowerChute Personal Edition OS Compatibility
This software supports numerous operating systems and processors.
Back-UPS Pro Features & Benefits
Availability
Customizable voltage sensitivity
Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.
Customizable voltage-transfer points
Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.
Cold-start capable
Provides temporary battery power when the utility power is out.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Energy Management Function
Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Protection
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
Manageability
USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Serviceability
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Simple battery replacement
Increases UPS availability by allowing quick, easy battery replacement.
Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Marketing Features
Energy Management Function
Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Secured and trusted checkout with

- Omschrijving
-
Details
Output
Output power capacity810Watts / 1.35 kVAMax Configurable Power (Watts)810Watts / 1.35 kVANominal Output Voltage120VOutput Frequency (sync to mains)50/60 Hz +/-1 HzTopologyLine InteractiveWaveform typeStepped approximation to a sinewaveOutput Connections(4) NEMA 5-15R (selector_surgetitle)(6) NEMA 5-15R (Battery Backup)Transfer Time8ms typical : 10 ms maximumInput
Nominal Input Voltage120VInput frequency50/60 Hz +/- 3 Hz (auto sensing)Input ConnectionsNEMA 5-15PCord Length1.83metersInput voltage range for main operations88 - 147VMaximum Input Current12.0ABatteries & Runtime
Battery typeMaintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproofIncluded Battery Modules1Typical recharge time16hour(s)Expected Battery Life (years)3 - 5Communications & Management
Interface Port(s)USBControl panelMulti-function LCD status and control consoleAudible AlarmAlarm when on battery : distinctive low battery alarm : overload continuous tone alarmSurge Protection and Filtering
Surge energy rating1080JoulesData Line ProtectionRJ45 10/100/1000 Base-T Ethernet protection, Coaxial cable for CATV/SATV/modem/Audio-Video (coax connector)FilteringFull time multi-pole noise filtering :5% of IEEE surge let-through : zero clamping response time: instantaneousPhysical
Maximum Height260mm, 26.0CMMaximum Width100mm, 10.0CMMaximum Depth368mm, 36.8CMNet Weight11.7KGShipping weight13.3KGShipping Height380mm, 38.0CMShipping Width241mm, 24.1CMShipping Depth500mm, 50.0CMColorBlackMaster Carton Units1.0Master Carton Weight13.3SCC Codes1073130433782 6Environmental
Operating Temperature0 - 40 °COperating Relative Humidity0 - 95 (non-condensing) %Operating Elevation0-3000metersStorage Temperature-15 - 40 °CStorage Relative Humidity0 - 95 (non-condensing) %Storage Elevation0-3000metersAudible noise at 1 meter from surface of unit45.0dBAConformance
ApprovalsFCC Part 15 Class B, NOM, TUV C-US certifiedSustainable Offer Status
RoHSCompliantREACHREACH: Contains No SVHCs - Reviews
-
Schrijf je eigen recensie
- Labels
-